Thanks Thanks:  0
HaHa HaHa:  0
Page 1 of 2 12 LastLast
Results 1 to 10 of 14

Thread: Extending trolling motor wire

  1. #1
    Join Date
    Aug 2014
    Location
    Baldwyn, Mississippi
    Posts
    1,290
    Post Thanks / Like

    Default Extending trolling motor wire


    I am needing to extend my trolling motor wire from front of boat to the back of the boat (16 foot boat) so nearly 16 foot of wire. What kind and size wire do I need for a minn kota 50 lb traxxis ?

  2. #2
    Join Date
    May 2013
    Location
    Central IL
    Posts
    1,783
    Post Thanks / Like

    Default

    6ga

  3. #3
    Join Date
    Oct 2014
    Location
    Lexington,SC
    Posts
    613
    Post Thanks / Like

    Default

    Since it's DC you gotta count the feet there and back............ @ 50 amps you need #4
    Three can keep a secret................If two of them are dead! (Benjamin Franklin)

  4. #4
    Join Date
    Apr 2010
    Location
    Wateloo,South Carolina
    Posts
    6,517
    Post Thanks / Like

    Default

    6 gauge wire will do the job great and last long time !!!!

    "What if you woke up today with only the things you thanked God for yesterday"
    "Life without God is like an unsharpened pencil - it has no point. "AMEN"

  5. #5
    "G"'s Avatar
    "G" is offline Super Duper Moderator - 2012 Crappie.Com Man of the year & 2018 Crappie.com Decade of Exceptional Service Awards * Crappie.com Supporter * Member Sponsor
    Join Date
    Aug 2008
    Location
    Belden, MS
    Posts
    95,225
    Post Thanks / Like

    Default

    6 guage is all you need
    I have spent most my life fishing........the rest I wasted.
    PROUD MEMBER OF TEAM GEEZER
    PICO Lures Field Rep

  6. #6
    Join Date
    Oct 2014
    Location
    Lexington,SC
    Posts
    613
    Post Thanks / Like

    Default

    If you run #6 it will work, but Don't be surprised when you want to run full speed you go hmmmm I don't seem to be going as fast as I used to.......... #6 is the minimum at your tm rating and feet of wire, It is alway's good practice to step up to the next gauge wire.......
    Three can keep a secret................If two of them are dead! (Benjamin Franklin)
    Likes Gobob LIKED above post

  7. #7
    M R Dux's Avatar
    M R Dux is offline Crappie.com Legend , 2018 Crappie.com Man of the Year * Crappie.com Supporter * Member Sponsor
    Join Date
    Mar 2008
    Location
    Benton,KY / KY Lake
    Posts
    7,488
    Post Thanks / Like

    Default

    I would go with #4 because if I have to do a job like that, I only want to do it once. #4 wire is a pain in the butt to work with. It is like trying to pull a 2x4 thru the maze of crap that is typically in the underside of our boat floors. That said, you will get much less power loss thru the large wire. The last 3 boats I have rigged got #4 wire from the TM batteries to the TM because I eventually went to what could be considered over-kill on my trolling motor sizes. I would rather have it and never need it than wish I had it and didn't.
    www.crappie-gills-n-more.com
    Podunk Ideas Pro Staff /test platform
    PICO Lures Field Rep
    Excel Boats Pro Staff
    Likes Cray, Gobob LIKED above post

  8. #8
    Speck's Avatar
    Speck is online now MO/MS Moderator and Fishing Legend * Member Sponsor
    Join Date
    Mar 2006
    Location
    MO
    Posts
    17,239
    Post Thanks / Like

    Default

    I agree with overkill on conductor size. #4 awg tinned copper. Be sure to use tinned copper conductor. You won't have near the problems with corrosion.


    Crazy Angler Pro Staff
    Crappie Logic Pro Staff

  9. #9
    Join Date
    Oct 2008
    Location
    Brandon, Mississippi
    Posts
    27,673
    Post Thanks / Like

    Default

    Ding Ding, we have a winner. I learned my lessons and spent the money. I got mine off ebay but I guess he sold out. Here's a Ebay link for $1.70 a foot. 4 AWG Gauge Black Ancor Marine Tinned Copper Boat Battery Cable Wire 20' MIN | eBay

    Quote Originally Posted by Speck View Post
    I agree with overkill on conductor size. #4 awg tinned copper. Be sure to use tinned copper conductor. You won't have near the problems with corrosion.
    proud member of "Team Cup"
    Likes ATM, "G", Speck LIKED above post

  10. #10
    Join Date
    Aug 2014
    Location
    Baldwyn, Mississippi
    Posts
    1,290
    Post Thanks / Like

    Default

    Quote Originally Posted by DonDon View Post
    Ding Ding, we have a winner. I learned my lessons and spent the money. I got mine off ebay but I guess he sold out. Here's a Ebay link for $1.70 a foot. 4 AWG Gauge Black Ancor Marine Tinned Copper Boat Battery Cable Wire 20' MIN | eBay
    so if im needing 16 feet of this wire in the link i really need 32 feet because i will need a piece to run both positive and negative correct? i am an idiot when it comes to wiring and electricity