Likes Likes:  0
Thanks Thanks:  0
HaHa HaHa:  0
Results 1 to 7 of 7

Thread: Motorguide Brute 750 - 12v/24v 50 lb thrust - amperage draw?

  1. #1
    Join Date
    Jan 2019
    Location
    Benton, KY
    Posts
    660
    Post Thanks / Like

    Default Motorguide Brute 750 - 12v/24v 50 lb thrust - amperage draw?


    I've got an older Motorguide, Model No. 750 Brute, 12/24 volt 50 lb thrust

    Does anyone know the amperage draw and rated thrust for the various levels?

    12 volt - setting 1, 2, 3, 4, 5

    24 volt - setting 1, 2, 3, 4, 5

    I've looked online for the amp ratings, but can't find a clear answer. The closest thing I've found is that a 12 volt 50 lb thrust draws 50 amps max, but what I can't figure out is if my trolling motor is rated for 50 lb thrust at 12 volt, or is it 50 lb thrust at 24 volt?

    The main reason I ask is that the boat has 3 each (red, white, black) of 8 AWG wires from the bow to the batteries in the rear, with each wire being about 18 ft long. The 3 wires are for the 12/24 system.

    If I am drawing 50 amps on 12 volts the 8 AWG is insufficient/too small to carry the amp demand - I apparently had a heat issue last summer at some point at the plug-in, the male plug melted a little bit. I have since replaced the plug and I'm trying to determine the cause and whether or not I need to eliminate the 12 volt option and simply stay on 24 volts. I just need some good data to base that decision on.

  2. #2
    Join Date
    Jul 2017
    Location
    MO
    Posts
    980
    Post Thanks / Like

    Default

    When you double the voltage, amperage is cut nearly in half, everything else equal. Say your motor requires 50 amps wide open with 12 volt, I believe you're probably looking at ~30 amps with 24 to do the same work.

  3. #3
    Join Date
    Jan 2019
    Location
    Benton, KY
    Posts
    660
    Post Thanks / Like

    Default

    Quote Originally Posted by Atimm693 View Post
    When you double the voltage, amperage is cut nearly in half, everything else equal. Say your motor requires 50 amps wide open with 12 volt, I believe you're probably looking at ~30 amps with 24 to do the same work.
    That's exactly what I was thinking, and why I think if I make it 24 volts full time I won't have any more issues.

  4. #4
    Cray's Avatar
    Cray is offline Crappie.com 2019 Man of Year, Supermod & Moderator of the Mechanics Forum * Crappie.com Supporter
    Join Date
    Oct 2010
    Location
    Byhalia,Mississippi
    Posts
    17,388
    Post Thanks / Like

    Default

    Usually a heat issue is caused by a bad connection. The bad connection cause higher resistance thus creating heat. 8 gauge at that length is more than sufficient for 12 or 24. My only concern about going straight 24 is going to be speed control.
    Proud Member of Team Geezer
    Charlie Weaver USN/ENC 1965-1979




  5. #5
    Join Date
    Jan 2019
    Location
    Benton, KY
    Posts
    660
    Post Thanks / Like

    Default

    Quote Originally Posted by Cray View Post
    Usually a heat issue is caused by a bad connection. The bad connection cause higher resistance thus creating heat. 8 gauge at that length is more than sufficient for 12 or 24. My only concern about going straight 24 is going to be speed control.
    Minn Kota recommends 4 AWG for 12 volts 50 lb thrust

    https://www.minnkotamotors.com/sites...le_1-22-19.pdf

  6. #6
    "G"'s Avatar
    "G" is offline Super Duper Moderator - 2012 Crappie.Com Man of the year & 2018 Crappie.com Decade of Exceptional Service Awards * Crappie.com Supporter * Member Sponsor
    Join Date
    Aug 2008
    Location
    Belden, MS
    Posts
    95,225
    Post Thanks / Like

    Default

    Quote Originally Posted by artcarney_agr View Post
    Minn Kota recommends 4 AWG for 12 volts 50 lb thrust

    https://www.minnkotamotors.com/sites...le_1-22-19.pdf

    Thats probably best...I have mine wired with 6 guage.....But my batterys are only 6 ft. away.
    I have spent most my life fishing........the rest I wasted.
    PROUD MEMBER OF TEAM GEEZER
    PICO Lures Field Rep

  7. #7
    Join Date
    Aug 2011
    Location
    Jonesboro, AR
    Posts
    532
    Post Thanks / Like

    Default

    Check wiring terminal connections for corrosion. That model tm has been out of production for a long time. If you are seeing black or green colored corrosion anywhere in the system, you are looking at an area of high resistance that may not be picked up by way of a meter. Also, the heat is generated at the point of resistance. So you may have already corrected your problem.
    I'd rather be fishing.