    Hi guys my dad bought our first non aluminum boat, a 20' Key West cuddy cabin with a 225 hp. My dad bought it this summer while I was out of state. He ran it fine, then left it tied up at his sister's dock for 2 weeks. Got a call from my uncle and said there was some standing water in it. There was a couple of inches of rain so I'm wondering about the bilge pump.

    Isn't the bilge pump supposed to run while the boat isn't running assuming the battery isn't dead? How do I check if it's direct wired? He said they put 2 plugs in it, I wasn't there so I have no idea what they plugged. I'm assuming it was drain hole plugs, would you be able to plug the bilge pump outlet?

    As of now I plan to check to see if it turns on, cleaning out the filter, and maybe install a bigger one for peace of mind since we plan to take it offshore.

    Just waiting on it to cool off to get a few things done with it, 95+ heat index in October is no fun.

    Thanks for any help, the whole boat thing is new to us.

  2. #2
    Join Date
    Dec 2016
    Location
    Kentucky
    Posts
    142
    Post Thanks / Like

    Default

    There's two different pumps one is manual only and one is auromatic, the automatic one has a float protruding out of it. When water pushes the float up it turns the pump on.
    Likes wicklundrh LIKED above post

  3. #3
    Redge is offline Crappie.com Legend - 2017 Man Of The Year
    Join Date
    Mar 2010
    Location
    OK
    Posts
    27,548
    Post Thanks / Like

    Default

    Quote Originally Posted by jwest4164 View Post
    There's two different pumps one is manual only and one is auromatic, the automatic one has a float protruding out of it. When water pushes the float up it turns the pump on.
    X2! I would check and see if you don’t have a switch labeled bilge. Mine is manual, just flip the switch it pumps. Guessing they plugged both the boat drain and livewell.
    Note I said guessing. Good luck and let us know what you figure out.


    Sent from my iPhone using Crappie.com Fishing mobile app
    Proud Member of Team Geezer!

  4. #4
    Join Date
    May 2007
    Location
    Ridgeway, South Carolina
    Posts
    2,737
    Post Thanks / Like

    Default

    Ok so it not running while sitting there sounds like it might be normal? Thanks fellas!
    Thanks Redge thanked you for this post

  5. #5
    Join Date
    Mar 2016
    Location
    vero beach fl
    Posts
    897
    Post Thanks / Like

    Default

    You will probably find a 2 position switch on the console for the pump. One position for manual operation, and the other for automatic. I don't recall there being an (off) position. If the boats got some age on it, it might be wise to replace all the pumps with new ones. Key West is very good about answering questions about issues you might have with their boats, so don't hesitate calling them with questions. I was having some wiring issues due to the prior owner, and they sent me an entire wiring detail for my model boat. The only issue I have with Key West and many boats in general is they dont give much consideration for getting at the various things to actually work on them.
    But that can be fixed also.